The Pump Runs with Odd Noise or Loudly.
Following are the common causes for a noisy or loud pump. If you need further info for troubleshooting, please contact CML.
1. Inhale Air
1.Check the tank for foam. 2.Check the volume of the tank: Recommended to properly evaluate the required volume for the pump with larger displacement. 3.Check the height of the oil suction filter: confirm whether the hydraulic oil volume is higher than the height of the suction filter to avoid sucking in the air. 4.Check the distance between suction and return: too close may cause vortex. 5. Check whether there is a gap in the oil suction joint: it is recommended to install the oil suction joint below the liquid level and wrap it with a tape seal.
2. Insufficient Flow
1. Check the filter: If the oil filter is clogged, please clean it (Recommended density of the filter is twice or more of the maximum flow rate). 2. Check the flow: the flow adjustment screw is not factory set. 3. Check the piping: the suction pipe is too long and the pipe diameter is too small, which may cause insufficient oil suction. 4. Check the hydraulic oil: the viscosity of the hydraulic oil increases due to the low temperature, which makes it difficult to inhale.
3. Poor Concentricity
Check the connection: loosen the screws at the connection, or check the operation process according to the installation instructions.
- Files Download
Variable Vane Pump with Cooling Circulation Pump VCM+CG catalog
Variable Vane Pump with Cooling Circulation Pump VCM+CG,model code, technical data, performance curve, product feature and application.
DownloadCML Variable displacement Vane Pump Catalog
CML Variable displacement Vane Pump Catalog model code, technical data, performance curve, product feature and application.
Download